logo
NANTONG HWATEK WIRES AND CABLE CO.,LTD.

FILS ET CÂBLE CIE., LTD DE HWATEK.

Aperçu ProduitsCâble de remplissage d'EV

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Certificat
Chine NANTONG HWATEK WIRES AND CABLE CO.,LTD. certifications
Chine NANTONG HWATEK WIRES AND CABLE CO.,LTD. certifications
merci infiniment de votre réponse rapide. Votre solution professionnelle de câble me dépanne, qualité de câble est très bonne. Elle adapte nos connecteurs

—— Gonalze

Votre qualité des produits au delà de mon imaginent, j'apprécie fortement votre grand appui, l'espoir ont une meilleure et plus profonde coopération à l'avenir.

—— Bharath

Je suis en ligne une discussion en ligne

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Image Grand :  TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Détails sur le produit:
Certification: ISO9001, CCC, RoHS
Conditions de paiement et expédition:
Quantité de commande min: 3 000
Prix: 0.5
Description de produit détaillée
Conducteur: Cuivre Matériau de gaine: PVC
Matériel d'isolation: TPE Forme du matériau: Fil rond
Tension nominale: AC450 / 750V Température nominale: -40 ~ + 90 ° C
Type de conducteur: Cuivre nu ou en conserve Matériau de gaine: TPU
Rayon de flexion minimum: 5xod Essai d'inflammabilité: IEC60332-1
Spécifications de fil: 3 × 2,5 + 2 × 0,75, 3 × 4 + 2 × 0,75, 3 × 6 + 2 × 0,75, 5 × 2,5 + 2 × 0,75, 5 × 4 + 2 × 0,75, 5 × 6 Mettez en référence actuel: 18a, 25a, 34a, 50a, 67a
Diamètre non blindé: 12,7 mm, 14,4 mm, 16,3 mm, 15,3 mm, 17,8 mm, 19,8 mm, 22,9 mm, 27,5 mm Quantité par rouleau: 305m, 610m ou comme demande
Paquet de transport: Roulé en bobines, emballés dans des palettes
Mettre en évidence:

IEC60332-1 Flammability Test EV Charging Cable

,

Minimum Bending Radius 5xOD Electric Vehicle Charging Cable

,

305m 610m Length EV Power Cable

TPE Insulated AC & DC 450V 750V EV Charging Power Cable
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 0
Certification
General Administration of Quality Supervision, Inspection and Quarantine
Certificate No. Product Types
CQC16011142377 EV-(R)SS, EV-(R)SSPS, EV-(R)S90S90, EV-(R)S90S90PS90, EV-(R)S90U, EV-(R)S90S90PU-450/750V
Structure Diagram
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 1
Reference standard: GB/T 33594-2017
Product Specifications
AC Types: EV-(R)S90U, EV-(R)S90S90PU-450/750V 1.0-70(2-5Cores)+0.5-0.75(P/P2)(1-10Cores)
Construction Details
  • Rated temperature: -40°C to +90°C
  • Rated voltage: AC 450/750V
  • Conductor: Stranded bare or tinned copper
  • Insulation material: TPE
  • Sheath material: TPU
  • Flexible construction with resistance to cold, oil (11 types), ozone, abrasion, UV, external pressure and thermal stress
  • Passes IEC60332-1 flammability test
  • Minimum bending radius: 5xOD
  • Easy installation
Applications: Suitable for all types of electric vehicles, charging piles, power stations, and charging stations.
Structural Parameters
Category Wire Specifications Reference Current (A) Diameter Unshielded (mm)
TPE | PU 3×2.5+2×0.75 18 12.7 | 11.1
3×4+2×0.75 25 14.4 | 12.8
3×6+2×0.75 34 16.3 | 14.5
5×2.5+2×0.75 18 15.3 | 13.7
5×4+2×0.75 25 17.8 | 16.0
5×6+2×0.75 34 19.8 | 17.8
5×10+2×0.75 50 22.9 | 20.7
5×16+2×0.75 67 27.5 | 25.1
Notes:
  1. Detailed dimensions are subject to product specifications
  2. Other specifications can be custom designed according to customer requirements
  3. Standard sheath colors are black or orange, with custom colors available
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 2
Company Profile

Founded in 2004 with $9 million USD capital investment, our headquarters factory in Kunshan covers 14,980 square meters.

In 2020, we established our Nantong facility with 100 million RMB capital investment covering 34,000 square meters.

Certifications: ISO9001, ISO14001, IATF16949, ISO13485

Product certifications: CCC, UL, CUL, CE, CSA, ETL

Management principles: HONESTY, INNOVATION, ENVIRONMENTAL PROTECTION

Certificates
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 3
Production Process
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 4
Shipping
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 5
Frequently Asked Questions
Q: What products do you supply?
A: We produce consumer electronics wires, hook-up wires, industrial cables, robot cables, EV charging cables, and new/green energy cables.
Q: What certifications do you have?
A: Our products have UL, CE, 3C, Dekra, CQC, TUV, Rohs, Reach, and ETL certifications.
Q: Can we get samples before ordering?
A: Yes, we can arrange samples for evaluation.
Q: What is your production lead time?
A: Standard lead time is 2-3 weeks, extending to 5-6 weeks during peak seasons.
Q: How do you ensure product quality?
A: We conduct pre-production sampling and final inspection before shipment.
Major Customers
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 6

Coordonnées
NANTONG HWATEK WIRES AND CABLE CO.,LTD.

Personne à contacter: Jimmy Wang

Téléphone: 17715039722

Envoyez votre demande directement à nous (0 / 3000)