Câble à un conducteur
Isolation flexible colorée du câble cuivre UL10533 FRPE de brin multi à un noyau
UL10455 Single Conductor with extruded FRPE insulation, 90 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 90℃ Flame: VW-1, FT1, FT2 Voltage ...
Câbles UL10455 isolés par PVC à un conducteur pour le câblage interne de matériel électronique
UL10455 Single conductor using extruded non-integral jacket, 90 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:90℃ Flame: ...
32- 16 câble cuivre à un noyau d'A.W.G. UL10063 avec l'isolation expulsée du PE/FRPE
UL10063 Single conductor with extruded insulation, 80 ℃, 300V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: Extruded PE or extruded FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V Rated Temperature:80℃ ...
Le PVC a isolé le câble UL1284 flexible à un noyau pour 8AWG de câblage interne - 1000kcmil
UL1284 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor :solid or stranded round Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V Rated Temperature:105℃ Flame: VW-1, FT1, FT2 ...
Isolation flexible à un noyau UL1185 de PVC de câblage cuivre pour le câblage d'appareils
UL1185 Single conductor using extruded non-integral jacket, 80 ℃, 300 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V Rated Temperature:80℃ Flame: ...
Câble unipolaire UL1115 de PVC, 1 fil flexible et câble 30AWG - 16AWG de conducteur
UL1115 Single conductor cable using non-integral jacket, 80 ℃, 300 V(insulation) ,600V(sheath) VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V...
Le PVC flexible à un noyau à un conducteur du fil UL1283 a isolé 8 A.W.G. - 2AWG
UL1283 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor :solid or stranded, or braided conductor consisting of 40-20 AWG strands Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage...
UL1028 câble à un conducteur isolé par PVC, A.W.G. du câble de fil électrique 22 - A.W.G. 6
UL1028 Single Conductor with Extruded Insulation, 105 ℃, 600 V , VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V Rated Temperature:105℃ Flame: VW-1, FT1, FT2 Oil ...
L'isolation à un conducteur de PVC du câble UL1032 avec le solide/a échoué le conducteur
UL1032 Single Conductor with Extruded Insulation, 90 C,1000 V OR 1200V, VW-1,60 deg C or 80 deg C Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:1000V or 1200v Rated Temperature: 90 OC ...